Item | Unit | HY-002-2g | HY-002-3g |
Ozone output | G/Hr | 2 | 3 |
Power | W | 60 | 80 |
Voltage | V/HZ | AC220/110V,50/60HZ | |
Concentration | Mg/L | 15-25 | |
Gas feeding | / | Dry clean air | |
Dimension (L*W*H) | CM | 23*18*40 | |
Unit weight | Kg | 6 | 6.5 |
Cooling method | / | Air cooling | |
Air flow | L/h | 16 | |
Attachments | Sets | Silicone tube, fuse, etc | |
Color | / | Silver |
No. | Applications |
1 | Space sterilization |
2 | Animal smell removal |
3 | Keep food in fresh condition |
4 | Baby production disinfection |
5 | Waste water treatment,aquarium water freshen |
6 | Wash fruit and vegetable, residual pesticide removal |
7 | Living room, bedroom, kitchen, WC, car, air purification |
8 | Remove formaldehyde, benzene and other harmful gas in furniture,new house |
No. | Installation Guide |
1 | The ozone generator should be installed in low humidity circumstance with temperature between 0℃ to 43℃ and good condition of air circulation for heat dispersing. |
2 | The ozone generator should be installed close to the mains. Lengthening the cable is not suggested. |
3 | To keep appropriate condition for heat dispersion, the ozone generator should be installed far from the heat source enough and the barriers around with distance no less than 0.6 meters. |
4 | Please ensure the feeding gas and ozone outlet is correctly connected. |
5 | The ozone generator and oxygen generator would be installed 1.2 meters above the floor, and the ozone delivery line must be 1 to 2 meters high than the mixer of gas and water,2meters high than the water holding jar to prevent water sucked in. |
Equipment status | Causes | Solutions | Remarks |
No power | 1. Power plug loose | Plug in 220V/50HZ power | |
2. No 220V voltage | |||
No gas output from outlet | 1. Regular inspection to know whether the internal wiring joint is loose | 1.Cut down the power,then opening the back cover to check the pipes or wirings | Be careful!Must cut down the power to open the back cover. |
2.Whether a block in the pipes | 2.Turn on the air pump switch | ||
3. Whether air pump switch was turned on or not | |||
Gas supply regular, no ozone output | 1. Whether ozone switch is turned on or not | 1.Turn on the ozone switch button | |
2.Concentration | 2. To adjust the concentration button | ||
Adjustment is 0 levels. | 3. Check the electrocircuit. | ||
3.Control panel is out of control | 4.To change the electrical discharge | ||
4.Electrical discharge is damaged | |||
Case leakage | 1.Ungrounded electrical application at your local | Power supply should be ungrounded electrical application | |
2.Humidity | 2.To install the ozone generator in dry place | ||
Operating machine’s fuse burn-out, or tripping | 1. Short Circuit | 1. Check the electrocircuit | |
2 Electrical discharge is damaged | 2. To change the electrical discharge | ||
Water store inside the machine | 1. A backflow of water from operating water treatment into the ozone generator tube | 1.To dry inner ozone generator tube | In case of water into machine during the running, it is necessary to stop the machine Immediately to check and remove the faults |
2.Humidity | 2. To dry the inner machine box | ||
3.Undisposed air source | 3.Drying process for air source |