| Equipment status |
Causes |
Solutions |
Remarks |
| No power |
1. Power plug loose |
Plug in 220V/50HZ power |
|
| 2. No 220V voltage |
| No gas output from outlet |
1. Regular inspection to know whether the internal wiring joint is loose |
1.Cut down the power,then opening the back cover to check the pipes or wirings |
Be careful!Must cut down the power to open the back cover. |
| 2.Whether a block in the pipes |
2.Turn on the air pump switch |
| 3. Whether air pump switch was turned on or not |
|
| Gas supply regular, no ozone output |
1. Whether ozone switch is turned on or not |
1.Turn on the ozone switch button |
|
| 2.Concentration |
2. To adjust the concentration button |
| Adjustment is 0 levels. |
3. Check the electrocircuit. |
| 3.Control panel is out of control |
4.To change the electrical discharge |
| 4.Electrical discharge is damaged |
|
| Case leakage |
1.Ungrounded electrical application at your local |
Power supply should be ungrounded electrical application |
|
| 2.Humidity |
2.To install the ozone generator in dry place |
| Operating machine’s fuse burn-out, or tripping |
1. Short Circuit |
1. Check the electrocircuit |
|
| 2 Electrical discharge is damaged |
2. To change the electrical discharge |
| Water store inside the machine |
1. A backflow of water from operating water treatment into the ozone generator tube |
1.To dry inner ozone generator tube |
In case of water into machine during the running, it is necessary to stop the machine Immediately to check and remove the faults |
| 2.Humidity |
2. To dry the inner machine box |
| 3.Undisposed air source |
3.Drying process for air source |